1.
Medicina (B.Aires) ; 80(1): 17-22, feb. 2020. ilus, tab
Article in Spanish | LILACS | ID: biblio-1125033

ABSTRACT

La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value (SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Pacemaker, Artificial/adverse effects , Heart Valve Prosthesis/adverse effects , Defibrillators, Implantable/adverse effects , Endocarditis/microbiology , Endocarditis/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Pacemaker, Artificial/microbiology , Reference Values , Heart Valve Prosthesis/microbiology , Reproducibility of Results , Sensitivity and Specificity , Prosthesis-Related Infections/diagnostic imaging , Defibrillators, Implantable/microbiology , Statistics, Nonparametric , Fluorodeoxyglucose F18
2.
Rev. bras. cir. cardiovasc ; 34(4): 458-463, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1020506

ABSTRACT

Abstract Introduction: Indications for cardiac devices have been increasing as well as the need for lead extractions as a result of infections, failed leads and device recalls. Powered laser sheaths, with a global trend towards the in-creasingly technological tools, meant to improve the procedure's outcome but have economic implications. Objective: The aim of this study is to demonstrate the experience of a Bra-zilian center that uses simple manual traction in most lead removals per-formed annually, questioning the real need for expensive and technically challenging new devices. Methods: This retrospective observational study included 35 patients who had a transvenous lead extraction in the period of a year between January 1998 and October 2014 at Hospital de Messejana Dr. Carlos Alberto Studart Gomes, in Fortaleza, CE, Brazil. Data were collected through a records review. They were evaluated based on age, type of device, dwelling time, indication for removal, technique used and immediate outcomes. Results: The median dwelling time of the devices was 46.22 months. Infec-tion, lead fracture and device malfunction were the most common indica-tions. Simple traction was the method of choice, used in 88.9% of the pro-cedures. Manual traction presented high success rates, resulting in com-plete removal without complications in 90% of the cases. Conclusion: This article suggests that lead extraction by simple manual traction can still be performed effectively in countries with economic diffi-culties as a first attempt, leaving auxiliary tools for a second attempt in case of failure or contraindications to the simple manual traction technique.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology , Device Removal/instrumentation , Catheter-Related Infections/microbiology , Bacterial Infections/microbiology , Catheters, Indwelling/adverse effects , Retrospective Studies , Defibrillators, Implantable , Device Removal/methods
3.
PAFMJ-Pakistan Armed Forces Medical Journal. 2014; 1 (1): S63-S66
in English | IMEMR | ID: emr-157517

ABSTRACT

The objective of the study was to determine the microbiological spectrum of cardiac implantable electronic device [CIED] infections. Case series Armed Forces Institute of Cardiology / National Institute of Heart Diseases AFIC/NIHD from January 2011 to Nov 2013. A total of 15 pus samples from patients with possible CIED infection out of 814 patients with implantable CIEDs were processed. Thirteen patients with positive cultures out of fifteen were included in the study. Clinical evidence of CIED infection included signs of inflammation and purulent drainage. A CIED infection was microbiologically confirmed based on culture yield. Blood cultures were carried out in all patients with suspected CIED infection along with trans-oesophageal echocardiography [TOE], wherever clinically indicated to exclude bacteremia and lead endocarditis. Sixty nine percent of patients with culture proven CIED infection were females and 31% were males. The mean age of patients was 61 years [range 53-70 years]. Devices included 11 PPMs, 1 ICD and 1 CRT. The most frequent organisms were gram-positive [77% of isolates]; with Coagulase-negative Staphylococci [CoNS] predominating in particular Methicillin Resistant Staphylococcus epidermidis [MRSE] in 46.4% cases followed by Methicillin Sensitive Staphylococcus epidermidis [MSSE] in 15%. Non tuberculous Mycobacterium fortuitium was isolated from pus in two patients; with PPM and ICD implants respectively. MRSA was isolated in only 01 PPM infection with evidence of lead endocarditis on TOE. Pseudomonas species was isolated from pus in one patient with CRT implant. CIED infections are more often caused by Staphylococci predominantly CoNS, although atypical Mycobacteria can be implicated


Subject(s)
Humans , Male , Female , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology , Nontuberculous Mycobacteria , Methicillin-Resistant Staphylococcus aureus , Echocardiography , Defibrillators, Implantable/adverse effects , Antibiotic Prophylaxis
4.
Rev. ANACEM (Impresa) ; 6(2): 80-83, ago. 2012. tab, graf
Article in Spanish | LILACS | ID: lil-687052

ABSTRACT

INTRODUCCIÓN: La implantación de marcapasos definitivo se realiza en portadores de alteraciones en la generación del impulso cardíaco y/o con trastornos de la conducción. OBJETIVO: Caracterizar el perfil clínico-epidemiológico de los pacientes portadores de marcapasos definitivo en la Unidad de Cardiología del Hospital Regional de La Serena, en el período julio - septiembre de 2011. MATERIAL Y MÈTODO: Estudio descriptivo, de corte transversal. Se revisaron 103 fichas clínicas de pacientes marcapaso definitivo mediante muestreo aleatorio en la Unidad de Cardiología del Hospital Regional de La Serena. Se incluyeron pacientes mayores de 15 años con trastornos en generación del impulso y/o conducción irreversible. Se recopilaron y analizaron datos mediante Microsoft Excel 2007, identificándose características como sexo, edad, ruralidad, comorbilidades, manifestaciones clínicas, presencia o ausencia de Enfermedad de Chagas y cardiopatía específica. Se consideró significativo un p<0,05. RESULTADOS: Del total de 103 pacientes, 47,1 por ciento fueron mujeres. La edad promedio fue 74,5 +/- 12 años. La ruralidad fue de 49,51 por ciento Las manifestaciones clínicas más frecuentes fueron síncope (37,24 por ciento), disnea (32,34 por ciento) y mareos (24,46 por ciento). Del total de pacientes, 22 por ciento presentaron serología positiva para Tripanosoma Cruzi, 38 por ciento negativa y 40 por ciento sin serología. DISCUSIÓN: La principal causa de indicación de marcapasos definitivo fue el bloqueo auriculoventricular completo, correlacionándose con la literatura. No se encontró significancia estadística entre la severidad de la clínica y tipo de trastorno de la conducción. Se observó significancia estadística en la asociación entre ruralidad y serología para Tripanosoma Cruzi positiva y/o sin serología.


INTRODUCTION: The implant of definitive pacemaker is indicated in electrical impulse generation disorders and/or hearth electrical conduction abnormalities. OBJETIVE: Characterize clinically and epidemiologically the profile of patients with definitive pacemaker in the Cardiology Unit of the La Serena Regional Hospital, between July and September 2011. MATERIAL AND METHOD: Descriptive transversal cut study. 103 medical records of DPM diagnosed patients were analyzed by simple random sampling in the Cardiology Unit of the La Serena Regional Hospital. Patients with electrical impulse generation disorders and/or hearth electrical conduction abnormalities aged > 18 years old were included. Data collecting and analyzing were realized by Microsoft Excel 2007. The studied variables included: sex, age, rurality, disease, clinical symptoms, presence or absence of Chagas Disease and cardiopathies. Odss Ratio (OR) was calculated in significant differences situations in order to evaluate risk associated. A p< 0.05 was considered significant. RESULTS: Of the total of patients, 47.1 percent was women. The average age was 74.5 +/- 12 years. Rurality condition was 49.51 percent Most frecuent clinical symptoms were syncope (37.24 percent), dyspnoea (32.34 percent), dizziness (24.46 percent).Of 103 patients, 22 percent tested positive for Tripanosoma Cruzi, 38 percent tested negative and 40 percent without serology test. DISCCUSSION: The main definitive pacemaker indication was Complete Atrioventricular block, wich agree the literature. The association between clinical severity and hearth conduction abnormality type was not significant. We observed statistically significant differences between rurality condition and positive and/or without serologic test for Tripanosoma Cruzi.


Subject(s)
Humans , Male , Adult , Female , Middle Aged , Aged, 80 and over , Heart Diseases/epidemiology , Heart Diseases/therapy , Pacemaker, Artificial/statistics & numerical data , Age and Sex Distribution , Chile , Comorbidity , Cross-Sectional Studies , Chagas Disease/epidemiology , Pacemaker, Artificial/microbiology , Serology , Trypanosoma cruzi/isolation & purification
6.
Rev. Fac. Cienc. Méd. (Córdoba) ; 64(2): 45-47, 2007. tab
Article in Spanish | LILACS | ID: lil-511498

ABSTRACT

Antecedentes: Dentro del síndrome de endocarditis infecciosa, se incluyen la infección de dispositivos endovasculares. el objetivo de la presentación fue avaluar las características clínicas y la evolución de la endocarditis relacionada a dispositivos electrónicos endovasculares. Casos clínicos: entre 2002 - 2007 fueron identificados 7 pacientes con edad promedio de 56,5 años. La presentación clínica fue en el 85,7% fiebre de origen desconocido, con un promedio de 28 días de evolución del cuadro. Los germenes aislados fueron estafilococo coagulasa negativo en 6 pacientes y estafilococo aureus en 1 paciente. El tratamiento se baso en la extracción del sistema y terapia antibiótica, salvo 1 caso que solo recibió tratamiento antibiótico. Hubo 2 (28,5%) muertes intrahospitalarias durante el seguimiento. Conclusión: La endocarditis relacionada a dispositivos es una entidad con elevada mortalidad. el diagnóstico temprano y la extracción del sistema son de vital importancia para el tratamiento y pronóstico.


BACKGROUND: Infective endocarditis includes the endovascular devices infection. The main objective was to evaluate the clinical characteristics and evolution of the endocarditis related to electronics devices. CASE REPORTS: Between 2002 - 2007 periods were identified 7 patients, age average of 56.5 years. The clinical presentation was fever of unknown origin in 85.7%, with a mean of 28 days of evolution. The microbiology isolated was coagulase-negative staphylococci in 6 patients and staphylococcus aureus in 1 patient. The treatment was complete system extraction and antibiotic therapy, except in 1 case that only received antibiotics. There were 2 deaths (28,5%) during in hospital follow-up. CONCLUSION: The endocarditis related to devices is a disease with high mortality. Early diagnosis and system extraction are very important for the treatment and prognosis.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Defibrillators, Implantable/adverse effects , Endocarditis/etiology , Fever of Unknown Origin/etiology , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/etiology , Device Removal , Endocarditis/therapy , Pacemaker, Artificial/microbiology
7.
Rev. chil. cardiol ; 23(2): 164-170, abr.-jun. 2004.
Article in Spanish | LILACS | ID: lil-419185

ABSTRACT

El uso de marcapasos definitivos y defibriladores automáticos implantables se encuentra en un creciente aumento a nivel mundial, incluyendo nuestro país, esperándose que la tasa de implantes siga experimentando un aumento sostenido en los próximos años. A pesar del progreso en las técnicas de implante y del diseño de estos dispositivos, las complicaciones infecciosas asociadas a su uso constituyen una preocupación permanente pues se relacionan con morbilidades potencialmente graves, especialmente el desarrollo de endocarditis infecciosa, incluyendo tasas variables de mortalidad, y un significativo incremento en los costos de salud. La aparición de complicaciones infecciosas asociadas al uso de estos dispositivos pueden ser precoces o tardías en relación al momento del implante, y pueden comprometer sólo el bolsillo del dispositivo o extenderse a tejidos más profundos y, a través de la colonización de el o los electrodos, afectar el endocardio mural y valvular. La mayor parte de las veces la infección del bolsillo se produce por la contaminación en el momento del implante o por la erosión, transcurrido un tiempo, de los tejidos que cubren el dispositivo. El diagnóstico de esta complicación exige al clínico un alto índice de sospecha pues la mayoría de los casos los síntomas y signos son sólo locales. En los casos de sospecha de endocarditis infecciosa, el ecocardiograma, especialmente la técnica transesofágica, constituye a la fecha el examen complementario de mayor rendimiento diagnóstico. Si bien la etiología puede ser variada, la mayor parte de las veces el agente aislado es el estafilococo aureus en las infecciones precoces y diversas cepas de estafilococo coagulasa negativo en el caso de las infecciones tardías, lo que debe considerarse en el momento de seleccionar la terapia antibiótica. Una ves diagnosticada la infección, el tratamiento más ampliamente aceptado consiste en una estrategia mixta, conformada por antibioterapia según cultivos y remoción de todo el sistema, dispositivo y electrodo(s), aun cuando no se haya demostrado infección de estos últimos. La extracción del sistema, la mayor parte de las veces mediante cirugía, conlleva sus propios riesgos, algunos potencialmente fatales. Sólo la implementación y cumplimiento de rigurosas normas de prevención podrá limitar la incidencia de esta temida complicación asociada al uso de marcapasos definitivos y defibriladores internos.


Subject(s)
Humans , Defibrillators, Implantable , Endocarditis, Bacterial/complications , Prosthesis-Related Infections/complications , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology , Anti-Bacterial Agents/therapeutic use , Gram-Negative Bacteria/pathogenicity , Gram-Positive Bacteria/pathogenicity , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/prevention & control , Endocarditis, Bacterial/therapy , Risk Factors , Replantation/standards , Device Removal/adverse effects
8.
Journal of Korean Medical Science ; : 291-293, 2004.
Article in English | WPRIM | ID: wpr-211512

ABSTRACT

We report the case of a 35-yr-old patient who presented with high fever and chills. He had undergone a patch closure of the ventricular septal defect 18 yr before. One year later, a VVI pacemaker was implanted via the right subclavian vein because of complete heart block. Nine years after that, a new VVI pacemaker with another right ventricular electrode was inserted controlaterally and the old pacing lead was abandoned. Trans-thoracic and trans-esophageal echocardiogram identified the pacemaker lead in the right ventricle (RV) attaching hyperechoic materials and also a fluttering round hyperechoic mass with a stalk in the RV outflow tract. Cultures in blood and pus from pacemaker lead grew Achromobacter xylosoxidans. A diagnosis of pacemaker lead endocarditis due to Achromobacter xylosoxidans was made. In this regards, the best treatment is an immediate removal of the entire pacing system and antimicrobial therapy.


Subject(s)
Adult , Humans , Male , Achromobacter denitrificans , Electrodes, Implanted/microbiology , Endocarditis/microbiology , Gram-Negative Bacterial Infections/diagnostic imaging , Heart Block/therapy , Pacemaker, Artificial/microbiology
10.
Rev. colomb. cardiol ; 7(4): 191-5, ago. 1999. ilus, graf
Article in Spanish | LILACS | ID: lil-293794

ABSTRACT

La endocarditis por marcapaso es una complicación infrecuente y grave, debida al implante de marcapaso definitivo transvenoso. El diagnóstico se puede sospechar por la presencia de fibre, escalofríos, compromiso sistémico o lesiones pulmonares posterior a la inserción del electrodo y generadores. Los estafilococos aureus y epidermidis son las bacterias causantes de la mayoría de casos. Se debe realizar precozmente un ecocardiograma tranesofágico multiplanar al ingreso del paciente para visualizar las vegetaciones y posible compromiso anatomofuncional valvular. Actualmente se recomienda retirar lo más pronto posible el electrodo y el generador del marcapaso, asociado a un tratamiento antibiótico de acuerdo a la bacteria causal durante un período de seis semanas.


Subject(s)
Humans , Endocarditis/diagnosis , Endocarditis/etiology , Endocarditis/physiopathology , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/microbiology
11.
Rev. cuba. cardiol. cir. cardiovasc ; 13(1): 19-25, ene.-jun. 1999. tab
Article in Spanish | LILACS | ID: lil-271108

ABSTRACT

Fueron analizadas retrospectivamente las historias clínicas de 24 pacientes con endocarditis infecciosa en el período comprendido entre enero de 1995 y diciembre de 1997, con el objetivo de conocer las características de este grupo. La mitad de los pacientes tenían implantados marcapasos permanentes y la tercera parte eran portadores de cardiopatías valvulares primitivas. La puerta de entrada se identificó en el 45,8 porciento de los pacientes y en casi las dos terceras partes de ellos fue la sepsis del bolsillo del marcapasos el inicio de la infección. Los microorganismos causales se determinaron en el 79,2 porciento y los gérmenes más frecuentes fueron el estafilococo coagulasa positivo, el estafilococo coagulasa negativo y el estreptococo viridans. La forma de resolución fue quirúrgica en 14 enfermos y médica en 2. Fallecieron 8 pacientes como consecuencia de complicaciones cardíacas y sépticas. Concluimos que debe realizarse una rigurosa profilaxis antibiótica a los pacientes con prótesis valvular cardíaca o con marcapasos permanentes ante cualquier instrumentación quirúrgica por el alto riesgo de que se presente la endocarditis infecciosa


Subject(s)
Antibiotic Prophylaxis , Endocarditis, Bacterial/microbiology , Pacemaker, Artificial/microbiology , Heart Valve Prosthesis/microbiology